New Year Sale - Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70dumps

3V0-42.20 Questions and Answers

Question # 6

An architect is helping an organization with the Logical Design of a Layer 2 bridging solution.

This information was gathered during the Assessment Phase:

  • Workloads are running on ESXi hosts.
  • Workloads are running on KVM hosts.
  • Workloads on hypervisors should use bridging services.
  • VLAN 50 is used for Tier-0 uplink connectivity.

Which selection should the architect include in their design? (Choose the best answer.)

A.

Create an NSX Edge Bridge Cluster and configure the bridging profile with VLAN 60.

B.

Create an NSX Edge Bridge Cluster and configure the bridging profile with VLAN 50.

C.

Create an ESXi Bridge Cluster and configure the bridging profile with VLAN 50.

D.

Create an ESXi Bridge Cluster and configure the bridging profile with VLAN 60.

Full Access
Question # 7

An architect is helping an organization with the Conceptual Design of an NSX-T Data Center solution.

This information was gathered by the architect during the Discover Task of the Engagement Lifecycle:

  • There are applications which use IPv6 addressing.
  • Network administrators are not familiar with NSX-T Data Center solutions.
  • Hosts can only be configured with two physical NICs.
  • There is an existing management cluster to deploy the NSX-T components.
  • Dynamic routing should be configured between the physical and virtual network.
  • There is a storage array available to deploy NSX-T components.

Which risk was documented by the architect? (Choose the best answer.)

A.

Network administrators are not familiar with NSX-T Data Center solutions.

B.

Dynamic routing should be configured between the physical and virtual network.

C.

There are applications which use IPv6 addressing.

D.

There is a storage array available to deploy NSX-T components.

Full Access
Question # 8

An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.

This information was gathered during a workshop:

  • There are six hosts and hardware has already been purchased.
  • Customer is planning a collapsed Management/Edge/Compute cluster.
  • Each host has two 10Gb NICs connected to a pair of switches.
  • There should be no single point of failure in any proposed design.

Which virtual switch design should the architect recommend to the organization? (Choose the best answer.)

A.

Create a vSphere Distributed Switch (vDS) for Management VMkernel traffic and assign one NIC. Also, create an NSX-T Virtual Distributed Switch (N-VDS) for overlay traffic and assign one NIC.

B.

Create an NSX-T Virtual Distributed Switch (N-VDS) for Management VMkernel traffic and assign one NIC. Also, create an NSX-T Virtual Distributed Switch (N-VDS) for overlay traffic and assign one NIC.

C.

Create an NSX-T Virtual Distributed Switch (N-VDS) for Management VMKernel and overlay traffic and assign both NICs.

D.

Create an NSX-T Virtual Distributed Switch (N-VDS) for Management VMkernel and overlay traffic and assign a new virtual NIC.

Full Access