Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.
How long must records related to this decision be maintained by the code official?
At each grinding, buffing, or wire brushing operation on magnesium, other than the rough finishing of casting, dust must be collected by means of suitable hoods or enclosures connected to a:
The fire code official has the right to enter a building to perform inspections in all of the following situations except:
Battery-charging areas for industrial trucks shall be protected with portable fire extinguishers which have a minimum rating of:
A local board of appeals may perform all of the following functions except:
Multiple smoke alarms installed within individual guest rooms of a hotel must comply with which of the following requirements?
Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds ___ lb.
When more than 500 chairs are used for an assembly event held in a gymnasium, they must be secured to the floor or:
Quantities of flammable liquid storage in a control area of an S Occupancy may be doubled when:
A building occupied for aerosol storage shall be classified as which of the following occupancy classifications?
The minimum fire-flow for a 3,700-sq. ft. two-family dwelling of Type VB construction with a sprinkler system is ___ GPM.
The use of listed portable unvented oil-burning heating appliances is prohibited in which of the following occupancies?
Platforms used for access to aboveground tanks storing flammable or combustible liquids shall be:
Blocks or piles of baled fiber shall be separated from adjacent storage by aisles which are not less than __ ft wide
When adequate openings are provided on only one exterior wall of a story in an office building, an automatic sprinkler system shall be installed when the wall opposite the openings is more than ___ ft. away.
A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds
Given: An inspection checklist serves as a reminder to the inspector of common items that need to be checked. Which of the following is often a problem with the use of inspection checklists?
The maximum time which a hazardous materials storage tank may be left unused, before safeguards as required by the code official are necessary, is ___ days.
A "control area" is defined by the fire code as a building or portion of a building within which the exempted amounts of ___ are allowed to be stored, dispensed, used, or handled.
A container in a clean-agent extinguishing system must be refilled or replaced when it shows a loss in original weight of more than five percent, or a loss in original pressure of more than ___ percent.
The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not open to the public, is __ lb. water capacity.