Question # 6

Given: A code official permits a sprinkler system to substitute for a required second exit from a small basement.

How long must records related to this decision be maintained by the code official?

A.

Five years

B.

Three years

C.

Until the building is sold

D.

For as long as the building and the condition exist

Full Access
Question # 7

At each grinding, buffing, or wire brushing operation on magnesium, other than the rough finishing of casting, dust must be collected by means of suitable hoods or enclosures connected to a:

A.

cloth screen arrestor.

B.

low-pressure cyclone.

C.

dry-type dynamic precipitator.

D.

liquid precipitation type of separator.

Full Access
Question # 8

The fire code official has the right to enter a building to perform inspections in all of the following situations except:

A.

vacant buildings at any time.

B.

factory floors with permission to enter.

C.

public spaces of a mall during normal business hours.

D.

interior space of a warehouse with an administrative warrant.

Full Access
Question # 9

Battery-charging areas for industrial trucks shall be protected with portable fire extinguishers which have a minimum rating of:

A.

4-A:20-B:C

B.

3-A:40-B:C

C.

2-A:10-B:C

D.

40-B:C

Full Access
Question # 10

A local board of appeals may perform all of the following functions except:

A.

waive requirements of the fire code.

B.

render interpretations of the fire code.

C.

approve alternate materials and types of construction.

D.

adopt rules and regulations for conducting its investigations.

Full Access
Question # 11

Multiple smoke alarms installed within individual guest rooms of a hotel must comply with which of the following requirements?

A.

Their batteries must be checked every six months.

B.

They must automatically sound a fire alarm throughout the hotel.

C.

They must initiate an automatic fire suppression or sprinkler system.

D.

They must be interconnected so that one alarm will activate all alarms within the guest rooms.

Full Access
Question # 12

Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds ___ lb.

A.

30

B.

100

C.

200

D.

220

Full Access
Question # 13

When more than 500 chairs are used for an assembly event held in a gymnasium, they must be secured to the floor or:

A.

be spaced at least 6 in. apart.

B.

be fastened together in groups of not less than 3.

C.

be fastened together in groups of not less than 6.

D.

be fastened together in groups of not less than 10.

Full Access
Question # 14

Quantities of flammable liquid storage in a control area of an S Occupancy may be doubled when:

A.

permission is granted by the chief.

B.

the control area exceeds 50,000 sq. ft.

C.

the building is protected with automatic sprinklers.

D.

the control area is provided with exhaust ventilation in accordance with fire code requirements.

Full Access
Question # 15

A building occupied for aerosol storage shall be classified as which of the following occupancy classifications?

A.

High-hazard Group H

B.

High-hazard Group H-2

C.

High-hazard Group H-3

D.

Group S-1

Full Access
Question # 16

The minimum fire-flow for a 3,700-sq. ft. two-family dwelling of Type VB construction with a sprinkler system is ___ GPM.

A.

875

B.

1,000

C.

1,313

D.

1,750

Full Access
Question # 17

The use of listed portable unvented oil-burning heating appliances is prohibited in which of the following occupancies?

A.

Groups A and B occupancies

B.

Groups B and F occupancies

C.

Groups R-3, M, S-1, and S-2 occupancies

D.

Groups A, E, I, R-1, R-2, R-3, and R-4 occupancies

Full Access
Question # 18

Platforms used for access to aboveground tanks storing flammable or combustible liquids shall be:

A.

at least 4 ft. wide.

B.

built of noncombustible construction.

C.

built of nonferrous, nonsparking metal.

D.

located no closer than 3 ft. to the side of the tank.

Full Access
Question # 19

Blocks or piles of baled fiber shall be separated from adjacent storage by aisles which are not less than __ ft wide

A.

3

B.

5

C.

8

D.

10

Full Access
Question # 20

When adequate openings are provided on only one exterior wall of a story in an office building, an automatic sprinkler system shall be installed when the wall opposite the openings is more than ___ ft. away.

A.

50

B.

75

C.

100

D.

150

Full Access
Question # 21

A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds

A.

225

B.

500

C.

1,000

D.

2,500

Full Access
Question # 22

Given: An inspection checklist serves as a reminder to the inspector of common items that need to be checked. Which of the following is often a problem with the use of inspection checklists?

A.

They become a public record.

B.

They are time-consuming to complete and file.

C.

They may not address all of the code violations which may be encountered.

D.

They may serve as a basis for legal appeal against the code official's actions.

Full Access
Question # 23

The maximum time which a hazardous materials storage tank may be left unused, before safeguards as required by the code official are necessary, is ___ days.

A.

30

B.

60

C.

90

D.

120

Full Access
Question # 24

A "control area" is defined by the fire code as a building or portion of a building within which the exempted amounts of ___ are allowed to be stored, dispensed, used, or handled.

A.

hazardous materials

B.

flammable liquids only

C.

combustible liquids only

D.

corrosive materials only

Full Access
Question # 25

A container in a clean-agent extinguishing system must be refilled or replaced when it shows a loss in original weight of more than five percent, or a loss in original pressure of more than ___ percent.

A.

3

B.

5

C.

10

D.

12

Full Access
Question # 26

The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not open to the public, is __ lb. water capacity.

A.

735

B.

1,000

C.

2,000

D.

2,500

Full Access